Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 854
Filtrar
1.
Eur J Clin Invest ; 53(10): e14060, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37409393

RESUMO

BACKGROUND: Cancer is a well-known risk factor for venous thromboembolism (VTE). A combined strategy of D-dimer testing and clinical pre-test probability is usually used to exclude VTE. However, its effectiveness is diminished in cancer patients due to reduced specificity, ultimately leading to a decreased clinical utility. This review article seeks to provide a comprehensive summary of how to interpret D-dimer testing in cancer patients. METHODS: In accordance with PRISMA standards, literature pertaining to the diagnostic and prognostic significance of D-dimer testing in cancer patients was carefully chosen from reputable sources such as PubMed and the Cochrane databases. RESULTS: D-dimers have not only a diagnostic value in ruling out VTE but can also serve as an aid for rule-in if their values exceed 10-times the upper limit of normal. This threshold allows a diagnosis of VTE in cancer patients with a positive predictive value of more than 80%. Moreover, elevated D-dimers carry important prognostic information and are associated with VTE reoccurrence. A gradual increase in risk for all-cause death suggests that VTE is also an indicator of biologically more aggressive cancer types and advanced cancer stages. Considering the lack of standardization for D-dimer assays, it is essential for clinicians to carefully consider the variations in assay performance and the specific test characteristics of their institution. CONCLUSIONS: Standardizing D-dimer assays and developing modified pretest probability models specifically for cancer patients, along with adjusted cut-off values for D-dimer testing, could significantly enhance the accuracy and effectiveness of VTE diagnosis in this population.


Assuntos
Produtos de Degradação da Fibrina e do Fibrinogênio , Neoplasias , Humanos , Neoplasias/sangue , Neoplasias/complicações , Neoplasias/diagnóstico , Valor Preditivo dos Testes , Fatores de Risco , Tromboembolia Venosa/sangue , Tromboembolia Venosa/diagnóstico , Tromboembolia Venosa/prevenção & controle , Bioensaio/normas , Sensibilidade e Especificidade
2.
Kidney360 ; 3(7): 1158-1168, 2022 07 28.
Artigo em Inglês | MEDLINE | ID: mdl-35919538

RESUMO

Background: Clinical use of biomarkers requires the development of standardized assays and establishment of cutoffs. Urinary C-C motif chemokine ligand 14 (CCL14) has been validated to predict persistent severe AKI in critically ill patients with established AKI. We now report on the performance of standardized cutoffs using a clinical assay. Methods: A second aim of the multicenter RUBY Study was to establish two cutoffs for the prediction of persistent severe AKI (defined as KDIGO stage 3 AKI for at least 72 consecutive hours). Patients who received renal replacement therapy (RRT) or died before achieving 72 hours in stage 3 AKI were also considered to have reached the end point. Results: A cutoff value for urinary CCL14 of 1.3 ng/ml was determined to achieve high sensitivity (91%; 95% CI, 84% to 96%), and 13 ng/ml achieved high specificity (93%; 95% CI, 89% to 96%). The cutoff of 1.3 ng/ml identifies the majority (91%) of patients who developed persistent severe AKI with a negative predictive value of 92%. The cutoff at 13 ng/ml had a positive predictive value of 72% (with a negative predictive value of 75%). In multivariable adjusted analyses, a CCL14 concentration between 1.3 and 13 ng/ml had an adjusted odds ratio (aOR) of 3.82 (95% CI, 1.73 to 9.12; P=0.001) for the development of persistent severe AKI compared with those with a CCL14 ≤1.3 ng/ml, whereas a CCL14 >13 ng/ml had an aOR of 10.4 (95% CI, 3.89 to 29.9; P<0.001). Conclusions: Using a clinical assay, these standardized cutoffs (1.3 and 13 ng/ml) allow for the identification of patients at high risk for the development of persistent severe AKI. These results have immediate utility in helping to guide AKI patient care and may facilitate future clinical trials.Clinical Trial registry name and registration number: Identification and Validation of Biomarkers of Acute Kidney Injury Recovery, NCT01868724.


Assuntos
Injúria Renal Aguda , Bioensaio , Quimiocinas CC , Injúria Renal Aguda/diagnóstico , Bioensaio/normas , Quimiocinas CC/análise , Humanos , Ligantes , Terapia de Substituição Renal
3.
Nucleic Acids Res ; 50(2): 601-616, 2022 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-34219162

RESUMO

RNA-binding proteins (RBPs) and their RNA ligands play many critical roles in gene regulation and RNA processing in cells. They are also useful for various applications in cell biology and synthetic biology. However, re-engineering novel and orthogonal RNA-RBP pairs from natural components remains challenging while such synthetic RNA-RBP pairs could significantly expand the RNA-RBP toolbox for various applications. Here, we report a novel library-vs-library in vitro selection strategy based on Phage Display coupled with Systematic Evolution of Ligands by EXponential enrichment (PD-SELEX). Starting with pools of 1.1 × 1012 unique RNA sequences and 4.0 × 108 unique phage-displayed L7Ae-scaffold (LS) proteins, we selected RNA-RBP complexes through a two-step affinity purification process. After six rounds of library-vs-library selection, the selected RNAs and LS proteins were analyzed by next-generation sequencing (NGS). Further deconvolution of the enriched RNA and LS protein sequences revealed two synthetic and orthogonal RNA-RBP pairs that exhibit picomolar affinity and >4000-fold selectivity.


Assuntos
Bioensaio/métodos , Biblioteca Gênica , Proteínas de Ligação a RNA/metabolismo , RNA/metabolismo , Aptâmeros de Nucleotídeos , Bioensaio/normas , Ensaio de Desvio de Mobilidade Eletroforética/métodos , Sequenciamento de Nucleotídeos em Larga Escala , Modelos Moleculares , RNA/química , Proteínas de Ligação a RNA/química , Projetos de Pesquisa , Técnica de Seleção de Aptâmeros , Relação Estrutura-Atividade , Ressonância de Plasmônio de Superfície/métodos
4.
Nat Protoc ; 16(12): 5533-5558, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34759382

RESUMO

Cell-based assays for compound screening and profiling are fundamentally important in life sciences, chemical biology and pharmaceutical research. Most cell assays measure the amount of a single reporter molecule or cellular endpoint, and require the use of fluorescence or other labeled materials. Consequently, there is high demand for label-free technologies that enable multiple biomolecules or endpoints to be measured simultaneously. Here, we describe how to develop, optimize and validate MALDI-TOF mass spectrometry (MS) cell assays that can be used to measure cellular uptake of transporter substrates, to monitor cellular drug target engagement or to discover cellular drug-response markers. In uptake assays, intracellular accumulation of a transporter substrate and its inhibition by test compounds is measured. In drug response assays, changes to multiple cellular metabolites or to abundant posttranslational protein modifications are monitored as reporters of drug activity. We detail a ten-part optimization protocol with every part taking 1-2 d that leads to a final 2 d optimized procedure, which includes cell treatment, transfer, MALDI MS-specific sample preparation, quantification using stable-isotope-labeled standards, MALDI-TOF MS data acquisition, data processing and analysis. Key considerations for validation and automation of MALDI-TOF MS cell assays are outlined. Overall, label-free MS cell-based assays offer speed, sensitivity, accuracy and versatility in drug research.


Assuntos
Bioensaio/normas , Drogas em Investigação/farmacologia , Ensaios de Triagem em Larga Escala/normas , Processamento de Proteína Pós-Traducional/efeitos dos fármacos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/normas , Animais , Transporte Biológico/efeitos dos fármacos , Biomarcadores/metabolismo , Linhagem Celular , Relação Dose-Resposta a Droga , Células HEK293 , Ensaios de Triagem em Larga Escala/instrumentação , Ensaios de Triagem em Larga Escala/métodos , Humanos , Marcação por Isótopo/métodos , Camundongos , Microglia/citologia , Microglia/efeitos dos fármacos , Microglia/metabolismo
5.
Biomark Med ; 15(18): 1721-1732, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34674546

RESUMO

Aim: There is a critical need to validate biofluid-based biomarkers as diagnostic and drug development tools for traumatic brain injury (TBI). As part of the TBI Endpoints Development Initiative, we identified four potentially predictive and pharmacodynamic biomarkers for TBI: astroglial markers GFAP and S100B and the neuronal markers UCH-L1 and Tau. Materials & methods: Several commonly used platforms for these four biomarkers were identified and compared on analytic performance and ability to detect gold standard recombinant protein antigens and to pool control versus TBI cerebrospinal fluid (CSF). Results: For each marker, only some assay formats could differentiate TBI CSF from the control CSF. Also, different assays for the same biomarker reported divergent biomarker values for the same biosamples. Conclusion: Due to the variability of TBI marker assay in performance and reported values, standardization strategies are recommended when comparing reported biomarker levels across assay platforms.


Lay abstract Traumatic brain injury (TBI) is a leading cause of mortality and morbidity around the world. There is a critical need to validate biofluid-based biomarker tests as diagnostic and drug development tools. For this study, we focused on four brain-derived proteins called GFAP, S100B, UCH-L1 and Tau. To measure these biomarker proteins in human biofluid, one relies on either commercial or home-brew assays. Here, we attempted to compare the performance of 2­4 assay formats for each biomarker. We compared their assay sensitivity, ability to detect 'gold standard' protein analyte we procured, as well as the ability to differentiated pooled TBI cerebrospinal fluid from healthy control cerebrospinal fluid. We found that there are high variabilities among TBI marker assays in assay performance, reported biomarker values and ability to differentiate TBI versus control biofluid. Thus, a standardization strategy is needed when comparing reported biomarker levels across assay platforms.


Assuntos
Bioensaio/normas , Biomarcadores/líquido cefalorraquidiano , Lesões Encefálicas Traumáticas/líquido cefalorraquidiano , Lesões Encefálicas Traumáticas/diagnóstico , Determinação de Ponto Final , Antígenos/metabolismo , Estudos de Casos e Controles , Proteína Glial Fibrilar Ácida/líquido cefalorraquidiano , Humanos , Proteínas Recombinantes/metabolismo , Padrões de Referência , Subunidade beta da Proteína Ligante de Cálcio S100/líquido cefalorraquidiano , Ubiquitina Tiolesterase/líquido cefalorraquidiano , Proteínas tau/líquido cefalorraquidiano
6.
Medicine (Baltimore) ; 100(37): e27220, 2021 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-34664859

RESUMO

ABSTRACT: The visualization of intrahepatic hepatitis B virus (HBV) DNA by in situ hybridization (ISH) has uncovered some interesting aspects of HBV life cycle at the single-cell level. In the current study, we intend to evaluate the reliability and robustness of this assay in the real-world clinical scenario and its relationship with currently available clinical biomarkers in chronic hepatitis B (CHB) patients.In this cross-sectional study, 94 CHB patients and 10 patients with non-HBV related liver diseases were enrolled. Liver biopsies and routine histopathology analysis were performed. Intrahepatic HBV DNA and viral antigens (HBsAg and HBcAg) were detected by ISH and immunohistochemistry (IHC), respectively. The basic biochemical and virological parameters such as alanine transaminase, serum HBV DNA, and serum HBsAg were measured.The HBV DNA-ISH assay showed 55.8% (53/94 cases) positive rate in CHB patients, no false positive was found in non-HBV related hepatitis. The IHC of HBsAg and HBcAg showed a positive rate of 94.7% (89/94 cases) and 19.5% (17/87 cases), respectively. Quantification of HBV DNA-ISH signal showed a significant correlation with serum HBV DNA (rs = 0.6223, P < .0001). In addition, the staining pattern of HBV DNA in situ in the context of collagen deposition informed the histopathological progression of chronic liver disease.The application of this ISH assay in evaluating intrahepatic viral replication in real-world CHB patients showed favorable performance. It can be a complementation to conventional liver histopathology examination and IHC detection of viral antigens. This methodology provides an intuitive assessment of virological and pathological state of CHB patients, and further supports clinical diagnosis and management.


Assuntos
Bioensaio/normas , Vírus da Hepatite B/genética , Hepatite B Crônica/diagnóstico , Adulto , Bioensaio/métodos , Bioensaio/estatística & dados numéricos , China , Estudos Transversais , Feminino , Antígenos do Núcleo do Vírus da Hepatite B/análise , Antígenos de Superfície da Hepatite B/análise , Hepatite B Crônica/fisiopatologia , Humanos , Fígado/patologia , Fígado/fisiopatologia , Masculino , Pessoa de Meia-Idade
7.
Clin Chem Lab Med ; 59(12): 1972-1980, 2021 11 25.
Artigo em Inglês | MEDLINE | ID: mdl-34496163

RESUMO

OBJECTIVES: Macrotroponin is due to cardiac troponin (cTn) binding to endogenous cTn autoantibodies. While previous studies showed a high incidence of macrotroponin affecting cTnI assays, reports of macrotroponin T, particularly without cTnI reactivity, have been rare. Although the clinical significance of macrotroponin is not fully understood, macroenzymes and complexes are recognised to cause confusion in interpretation of laboratory results. The potential for adverse clinical consequences due to misinterpretation of affected results is very high. METHODS: We describe four cases of macrotroponin T with persistently low high sensitivity cTnT (hs-cTnT) by the 9 min compared to the 18 min variant of the assay. Three cases were serendipitously identified due to the use of a lot number of Roche hs-cTnT affected by non-reproducible results, necessitating measurement of cTnT in duplicate. We identified and characterised these macrotroponin specimens by immunoglobulin depletion (Protein A and PEG precipitation), mixing studies with EDTA and recombinant cTnT. RESULTS: In cases of macro-cTnT, a lower result occurred on the hs-cTnT using the 9 min compared to 18 min variant assay (ratio of 9-18 min hs-cTnT <0.80). Mixing studies with recombinant cTnT or EDTA demonstrated a difference in recovery vs. controls. One of these patients demonstrated a high molecular weight complex for cTnI and cTnT demonstrating a macrocomplex involving both cTn. This patient demonstrated a rise and fall in cTn when measured by several commercial assays consistent with genuine acute cardiac injury. CONCLUSIONS: We identified several cases of macro-cTnT and described associated clinical and biochemical features.


Assuntos
Autoanticorpos , Bioensaio , Troponina T , Autoanticorpos/imunologia , Bioensaio/normas , Biomarcadores , Humanos , Troponina I/análise , Troponina T/análise , Troponina T/imunologia
8.
Ann Clin Lab Sci ; 51(4): 584-586, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34452901

RESUMO

In this study, we evaluated the analytical interference of glycolic acid on several lactate assays that use lactate oxidase and dehydrogenase. Herein, we tested the effect of different concentrations of glycolic acid (0.01-46mM) on the lactate assay by using central lab and point of care (POCT) analyzers: Radiometer ABL 800, Beckman AU480, Roche Cobas c502, and Abbott i-STAT. Glycolic acid concentrations as low as 0.12mM resulted in a ≥20% positive bias in lactate assay on the ABL 800 and a concentration of approximately 0.23mM resulted in >20% on the Roche Cobas c502 and Abbott i-STAT. A significant lactate gap is found at concentrations >0.06mM between the Radiometer ABL 800 and Roche Cobas c502/Abbott i-STAT. However, at concentrations ≥0.92mM, the lactate gap is very significant among all three platforms. Falsely elevated lactate levels could result in misdiagnosis.


Assuntos
Bioensaio/normas , Erros de Diagnóstico/prevenção & controle , Glicolatos/envenenamento , Ácido Láctico/sangue , Sistemas Automatizados de Assistência Junto ao Leito/normas , Diagnóstico Diferencial , Humanos
9.
Parasit Vectors ; 14(1): 347, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-34210362

RESUMO

BACKGROUND: Long-lasting insecticidal nets (LLINs) have played an important role in reducing the global malaria burden since 2000. They are a core prevention tool used widely by people at risk of malaria. The Vector Control Prequalification mechanism of the Word Health Organization (WHO-Vector Control PQ) established the testing and evaluation guidelines for LLINs before registration for public use. In the present study, two new brands of deltamethrin-impregnated nets (Yahe® LN and Panda® Net 2.0) were evaluated in an experimental hut against wild pyrethroid-resistant Anopheles gambiae s.l. in M'Bé nearby Bouaké, central Côte d'Ivoire. METHODS: The performance of Yahe® LN and Panda® Net 2.0 was compared with that of PermaNet 2.0, conventionally treated nets (CTN), and untreated net to assess the blood-feeding inhibition, deterrence, induced exophily, and mortality. RESULTS: Cone bioassay results showed that Panda® Net 2.0, PermaNet 2.0 and Yahe® LN (both unwashed and washed 20 times) induced > 95% knockdown or > 80% mortality of the susceptible Anopheles gambiae Kisumu strain. With the pyrethroid-resistant M'Bé strain, mortality rate for all treated nets did not exceed 70%. There was a significant reduction in entry and blood feeding (p < 0.05) and an increase in exophily and mortality rates (p < 0.05) with all treatments compared to untreated nets, except the CTNs. However, the personal protection induced by these treated nets decreased significantly after 20 washes. The performance of Panda® Net 2.0 was equal to PermaNet® 2.0 in terms of inhibiting blood feeding, but better than PermaNet® 2.0 in terms of mortality. CONCLUSION: This study showed that Yahe® LN and Panda® Net 2.0 met the WHO Pesticide Evaluation Scheme (WHOPES) criteria to undergo phase III trial at the community level. Due to an increasing spread and development of pyrethroid resistance in malaria vectors, control of malaria transmission must evolve into an integrated vector management relying on a large variety of efficient control tools.


Assuntos
Anopheles/efeitos dos fármacos , Bioensaio/normas , Resistência a Inseticidas , Mosquiteiros Tratados com Inseticida/normas , Inseticidas/farmacologia , Mosquitos Vetores/efeitos dos fármacos , Nitrilas/farmacologia , Piretrinas/farmacologia , Animais , Anopheles/fisiologia , Bioensaio/métodos , Ensaios Clínicos Fase II como Assunto , Côte d'Ivoire , Malária/parasitologia , Malária/prevenção & controle , Controle de Mosquitos/métodos , Controle de Mosquitos/normas , Mosquitos Vetores/parasitologia
10.
Anal Biochem ; 634: 114291, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34161831

RESUMO

Calcitonin gene-related peptide (CGRP) is critical for the pathophysiology of migraine, and four therapeutic antibodies targeting CGRP and its corresponding receptors have been approved by the Food and Drug Administration (FDA), while many others are in the different stages of clinical trials. Bioactivity determination is essential for the quality control and clinical application of therapeutic monoclonal antibodies (mAbs). However, no bioassay has been reported to date. In this study, we developed a reporter gene assay (RGA) based on SK-N-MC cells stably expressing firefly luciferase driven by cAMP response element (CRE). The key assay parameters were optimized according to signal-to-noise (SNR), the response value, and the fitted dose-response curve. Validation of the RGA in accordance with ICH-Q2 guidelines showed that the method had good specificity, accuracy, linearity, and precision. The established RGA can be utilized as a reference method for release testing and stability studies of relevant antibodies.


Assuntos
Anticorpos Monoclonais/farmacologia , Bioensaio/métodos , Peptídeo Relacionado com Gene de Calcitonina/imunologia , Genes Reporter , Transtornos de Enxaqueca/tratamento farmacológico , Anticorpos Monoclonais/metabolismo , Bioensaio/normas , Peptídeo Relacionado com Gene de Calcitonina/metabolismo , Antagonistas do Receptor do Peptídeo Relacionado ao Gene de Calcitonina/farmacologia , Linhagem Celular , Células HEK293 , Humanos , Luciferases de Vaga-Lume/metabolismo , Transtornos de Enxaqueca/metabolismo , Sensibilidade e Especificidade
11.
RNA Biol ; 18(12): 2363-2375, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33938388

RESUMO

Kinetic characterization of ribosomal translocation is important for understanding the mechanism of elongation in protein synthesis. Here we have optimized a popular fluorescent-mRNA based translocation assay conducted in stopped-flow, by calibrating it with the functional tripeptide formation assay in quench-flow. We found that a fluorescently labelled mRNA, ten bases long from position +1 (mRNA+10), is best suited for both assays as it forms tripeptide at a fast rate equivalent to the longer mRNAs, and yet produces a large fluorescence change upon mRNA movement. Next, we compared the commonly used peptidyl tRNA analog, N-acetyl-Phe-tRNAPhe, with the natural dipeptidyl fMet-Phe-tRNAPhe in the stopped-flow assay. This analog translocates about two times slower than the natural dipeptidyl tRNA and produces biphasic kinetics. The rates reduce further at lower temperatures and with higher Mg2+ concentration, but improve with higher elongation factor G (EF-G) concentration, which increase both rate and amplitude of the fast phase significantly. In summary, we present here an improved real time assay for monitoring mRNA-translocation with the natural- and an N-Ac-analog of dipeptidyl tRNA.


Assuntos
Bioensaio/normas , Fatores de Alongamento de Peptídeos/metabolismo , Biossíntese de Proteínas , RNA Mensageiro/metabolismo , Aminoacil-RNA de Transferência/genética , RNA de Transferência/metabolismo , Ribossomos/metabolismo , Guanosina Trifosfato/metabolismo , Humanos , Cinética , Fatores de Alongamento de Peptídeos/genética , RNA Mensageiro/genética , RNA de Transferência/genética , Ribossomos/genética , Espectrometria de Fluorescência
12.
Front Immunol ; 12: 636420, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33936049

RESUMO

The expanded availability of adalimumab products continues to widen patient access and reduce costs with substantial benefit to healthcare systems. However, the long-term success of these medicines is highly dependent on maintaining consistency in quality, safety and efficacy while minimizing any risk of divergence during life-cycle management. In recognition of this need and demand from global manufacturers, the World Health Organization (WHO) Expert Committee on Biological standardization established the WHO 1st International standard (IS) for Adalimumab (coded 17/236) in October 2019 with a defined unitage ascribed to each of the individual bioactivities evaluated in the study namely, TNF-α binding, TNF-α neutralization, complement dependent cytotoxicity and antibody-dependent cellular cytotoxicity. For development of the IS, two candidate standards were manufactured as per WHO recommendations. Analysis of extensive datasets generated by testing of a common set of samples including the candidate standards by multiple stakeholders including regulatory agencies using their own qualified assays in a large international collaborative study showed comparable biological activity for the tested candidates for the different activities. Use of a common standard significantly decreased the variability of bioassays and improved agreement in potency estimates. Data from this study clearly supports the utility of the IS as an important tool for assuring analytical assay performance, for bioassay calibration and validation, for identifying and controlling changes in bioactivity during life-cycle management and for global harmonization of adalimumab products. In addition, in a separate multi-center study which included involvement of hospital and clinical diagnostic laboratories, the suitability of the adalimumab IS for therapeutic drug monitoring assays was examined by analysis of data from testing of a common blind coded panel of adalimumab spiked serum samples representative of the clinical scenario along with the IS and in-house standards in diverse immunoassays/platforms. Both commercially available and in-house assays that are routinely used for assessing adalimumab trough levels were included. Excellent agreement in estimates for adalimumab content in the spiked samples was observed regardless of the standard or the method with inter-laboratory variability also similar regardless of the standard employed. This data, for the first time, provides support for the extended applicability of the IS in assays in use for therapeutic drug monitoring based on the mass content of the IS. The adalimumab IS, in fulfilling clinical demand, can help toward standardizing and harmonizing clinical monitoring assays for informed clinical decisions and/or personalized treatment strategies for better patient outcomes. Collectively, a significant role for the adalimumab IS in assuring the quality, safety and efficacy of adalimumab products globally is envisaged.


Assuntos
Adalimumab/uso terapêutico , Bioensaio/normas , Medicamentos Biossimilares/uso terapêutico , Monitoramento de Medicamentos/normas , Inibidores do Fator de Necrose Tumoral/uso terapêutico , Fator de Necrose Tumoral alfa/antagonistas & inibidores , Adalimumab/efeitos adversos , Animais , Especificidade de Anticorpos , Medicamentos Biossimilares/efeitos adversos , Medicamentos Biossimilares/normas , Células CHO , Cricetulus , Células HEK293 , Humanos , Células Jurkat , Controle de Qualidade , Padrões de Referência , Equivalência Terapêutica , Inibidores do Fator de Necrose Tumoral/efeitos adversos , Inibidores do Fator de Necrose Tumoral/normas , Fator de Necrose Tumoral alfa/imunologia , Células U937 , Organização Mundial da Saúde
13.
Sci Rep ; 11(1): 10398, 2021 05 17.
Artigo em Inglês | MEDLINE | ID: mdl-34001964

RESUMO

We report a shipping container that enables a disruptive logistics for cytogenetic biodosimetry for radiation countermeasures through pre-processing cell culture during transportation. The container showed precise temperature control (< 0.01 °C) with uniform sample temperature (< 0.1 °C) to meet the biodosimetry assay requirements. Using an existing insulated shipping box and long shelf life alkaline batteries makes it ideal for national stockpile. Dose curve of cytogenetic biodosimetry assay using the shipping container showed clear dose response and high linear correlation with the control dose curve using a laboratory incubator (Pearson's correlation coefficient: 0.992). The container's ability of pre-processing biological samples during transportation could have a significant impact on radiation countermeasure, as well as potential impacts in other applications such as biobanking, novel molecular or cell-based assays or therapies.


Assuntos
Bancos de Espécimes Biológicos/normas , Liberação Nociva de Radioativos , Manejo de Espécimes/normas , Meios de Transporte/normas , Bioensaio/normas , Análise Citogenética/normas , Citogenética/normas , Humanos , Navios/normas
14.
Sci Rep ; 11(1): 10880, 2021 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-34035340

RESUMO

A proper internal standard choice is critical for accurate, precise, and reproducible mass spectrometry-based proteomics assays. Synthetic isotopically labeled (SIL) proteins are currently considered the gold standard. However, they are costly and challenging to obtain. An alternative approach uses SIL peptides or SIL "winged" peptides extended at C- or/and N-terminus with an amino acid sequence or a tag cleaved during enzymatic proteolysis. However, a consensus on the design of a winged peptide for absolute quantification is missing. In this study, we used human serum albumin as a model system to compare the quantitative performance of reference SIL protein with four different designs of SIL winged peptides: (i) commercially available SIL peptides with a proprietary trypsin cleavable tag at C-terminus, (ii) SIL peptides extended with five amino acid residues at C-terminus, (iii) SIL peptides extended with three and (iv) with five amino acid residues at both C- and N-termini. Our results demonstrate properties of various SIL extended peptides designs, e.g., water solubility and efficiency of trypsin enzymatic cleavage with primary influence on quantitative performance. SIL winged peptides extended with three amino acids at both C- and N-termini demonstrated optimal quantitative performance, equivalent to the SIL protein.


Assuntos
Bioensaio/métodos , Peptídeos/química , Proteínas/análise , Sequência de Aminoácidos , Bioensaio/normas , Humanos , Marcação por Isótopo , Cinética , Peptídeos/síntese química , Conformação Proteica , Proteínas/química , Proteólise , Proteômica/métodos , Padrões de Referência , Solubilidade , Solventes , Tripsina/metabolismo
15.
Pharm Biol ; 59(1): 537-545, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33941036

RESUMO

CONTEXT: Owing to the complexity of chemical ingredients in traditional Chinese medicine (TCM), it is difficult to maintain quality and efficacy by relying only on chemical markers. OBJECTIVE: Lianhua Qingwen capsule (LHQW) was selected as an example to discuss the feasibility of a bioassay for quality control. MATERIALS AND METHODS: Network pharmacology was used to screen potential targets in LHQW with respect to its anti-inflammatory effects. An in vitro cell model was used to validate the prediction. An anti-inflammatory bioassay was established for the quality evaluation of LHQW in 40 batches of marketed products and three batches of destructed samples. RESULTS: The tumor necrosis factor/interleukin-6 (TNF/IL-6) pathway via macrophage was selected as the potential target of LHQW. The IC50 value of LHQW on RAW 264.7 was 799.8 µg/mL. LHQW had significant inhibitory effects on the expression of IL-6 in a dose-dependent manner (p < 0.05). The anti-inflammatory biopotency of LHQW was calculated based on the inhibitory bioactivity on IL-6. The biopotency of 40 marketed samples ranged from 404 U/µg to 2171 U/µg, with a coefficient of variation (CV) of 37.91%. By contrast, the contents of forsythin indicated lower CV (28.05%) than the value of biopotency. Moreover, the biopotencies of destructed samples declined approximate 50%, while the contents of forsythin did not change. This newly established bioassay revealed a better ability to discriminate the quality variations of LHQW as compared to the routine chemical determination. CONCLUSIONS: A well-established bioassay may have promising ability to reveal the variance in quality of TCM.


Assuntos
Anti-Inflamatórios/normas , Bioensaio/normas , Medicamentos de Ervas Chinesas/normas , Mediadores da Inflamação/antagonistas & inibidores , Controle de Qualidade , Animais , Anti-Inflamatórios/química , Anti-Inflamatórios/farmacologia , Bioensaio/métodos , Relação Dose-Resposta a Droga , Composição de Medicamentos/métodos , Composição de Medicamentos/normas , Medicamentos de Ervas Chinesas/química , Medicamentos de Ervas Chinesas/farmacologia , Mediadores da Inflamação/metabolismo , Camundongos , Células RAW 264.7
16.
AAPS J ; 23(3): 64, 2021 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-33942188

RESUMO

In the absence of regulatory guidelines for the bioanalysis of new drug modalities, many of which contain multiple functional domains, bioanalytical strategies have been carefully designed to characterize the intact drug and each functional domain in terms of quantity, functionality, biotransformation, and immunogenicity. The present review focuses on the bioanalytical challenges and considerations for RNA-based drugs, bispecific antibodies and multi-domain protein therapeutics, prodrugs, gene and cell therapies, and fusion proteins. Methods ranging from the conventional ligand binding assays and liquid chromatography-mass spectrometry assays to quantitative polymerase chain reaction or flow cytometry often used for oligonucleotides and cell and gene therapies are discussed. Best practices for method selection and validation are proposed as well as a future perspective to address the bioanalytical needs of complex modalities.


Assuntos
Bioensaio/normas , Desenvolvimento de Medicamentos/normas , Guias como Assunto , Anticorpos Biespecíficos/análise , Anticorpos Biespecíficos/uso terapêutico , Bioensaio/métodos , Terapia Baseada em Transplante de Células e Tecidos , Cromatografia Líquida/normas , Desenvolvimento de Medicamentos/métodos , Citometria de Fluxo/normas , Terapia Genética , Espectrometria de Massas/normas , Oligonucleotídeos/análise , Oligonucleotídeos/uso terapêutico , Pró-Fármacos/análise , Pró-Fármacos/uso terapêutico , RNA/análise , RNA/uso terapêutico , Proteínas Recombinantes de Fusão/análise , Proteínas Recombinantes de Fusão/uso terapêutico
17.
J Steroid Biochem Mol Biol ; 212: 105917, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34010687

RESUMO

An intralaboratory study assessing assay variability and bias for determination of serum total 25-hydroxyvitamin D [25(OH)D] was conducted by the Vitamin D Standardization Program (VDSP). Thirteen assays for serum total 25(OH)D were evaluated in a single laboratory including 11 unique immunoassays and one liquid chromatography - tandem mass spectrometry (LC-MS/MS) assay. Fifty single-donor serum samples, including eight samples with high concentrations of 25(OH)D2 (> 30 nmol/L), were assigned target values for 25(OH)D2 and 25(OH)D3 using reference measurement procedures (RMP). Using four replicate measurements for each sample, the mean total percent coefficient of variation (%CV) and mean % bias from the target values were determined for each assay using the 50 single-donor samples and a 42-sample subset, which excluded 8 high 25(OH)D2 concentration samples, and compared with VDSP performance criteria of ≤ 10 % CV and ≤ ±5 % mean bias. All 12 assays achieved the performance criterion for % CV, and 9 of the 12 assays were within ≤ ±5 % mean bias. The Fujirebio Inc. assay exhibited the lowest %CV and highest percentage of individual measurements within ≤ ±5 % mean bias. Ten immunoassays exhibited changes in response due to the high 25(OH)D2 samples with Abbott, Biomérieux, DiaSorin, DIAsource, and IDS-iSYS assays having the largest deviations. The Fujirebio Inc. and Beckman Coulter assays were only minimally affected by the presence of the high 25(OH)D2 samples. Samples with high concentrations of 25(OH)D2 provided a critical performance test for immunoassays indicating that some assays may not have equal response or recovery for 25(OH)D2 and 25(OH)D3.


Assuntos
Bioensaio/normas , Imunoensaio/normas , Vitamina D/análogos & derivados , Vitaminas/sangue , Viés , Cromatografia Líquida , Humanos , Laboratórios , Padrões de Referência , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem , Vitamina D/sangue
18.
Bioanalysis ; 13(8): 609-619, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33847160

RESUMO

The 13th Global CRO Council (GCC) closed forum for bioanalysis was held in New Orleans, LA, USA on 5 April 2019. This GCC meeting was organized to discuss the contents of the 2019 ICH M10 Bioanalytical Method Validation Draft Guideline published in February 2019 and consolidate the feedback of the GCC members. While ICH M10 will cover requirements for reference standards, one of the biggest challenges facing the CRO community is the lack of consistency and completeness of Certificates of Analysis for reference standards used in regulated bioanalysis. Similar challenges exist with critical reagents (e.g., capture and detection antibodies) used for assays supporting biologics. The recommendations provided in this publication are the minimum requirements for the content that GCC members believe should be included in Certificates of Analysis for reference standards obtained from commercial vendors, sponsors and compendial suppliers, for use in regulated bioanalytical studies. In addition, recommendations for internal standards, metabolites and critical reagents are discussed.


Assuntos
Anticorpos/análise , Bioensaio/normas , Humanos , Padrões de Referência
19.
J Extracell Vesicles ; 10(4): e12059, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33664936

RESUMO

Extracellular vesicles (EVs) have drawn huge attention for diagnosing myriad of diseases, including cancer. However, the EV detection and analyses procedures often lack much desired sample standardization. To address this, we used well-characterized recombinant EVs (rEVs) for the first time as a biological reference material in developing a fiber optic surface plasmon resonance (FO-SPR) bioassay. In this context, EV binding on the FO-SPR probes was achieved only with EV-specific antibodies (e.g. anti-CD9 and anti-CD63) but not with non-specific anti-IgG. To increase detection sensitivity, we tested six different combinations of EV-specific antibodies in a sandwich bioassay. Calibration curves were generated with two most effective combinations (anti-CD9/Banti-CD81 and anti-CD63/Banti-CD9), resulting in 103 and 104 times higher sensitivity than the EV concentration in human blood plasma from healthy or cancer patients, respectively. Additionally, by using anti-CD63/Banti-CD9, we detected rEVs spiked in cell culture medium and HEK293 endogenous EVs in the same matrix without any prior EV purification or enrichment. Lastly, we selectively captured breast cancer cell EVs spiked in blood plasma using anti-EpCAM antibody on the FO-SPR surface. The obtained results combined with FO-SPR real-time monitoring, fast response time and ease of operation, demonstrate its outstanding potential for EV quantification and analysis.


Assuntos
Bioensaio/métodos , Bioensaio/normas , Técnicas Biossensoriais/métodos , Calibragem , Vesículas Extracelulares/química , Anticorpos/química , Tecnologia de Fibra Óptica/métodos , Células HEK293 , Humanos , Células MCF-7 , Neoplasias/química , Neoplasias/diagnóstico , Plasma/química , Padrões de Referência , Ressonância de Plasmônio de Superfície/métodos
20.
Basic Clin Pharmacol Toxicol ; 128(5): 642-648, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33665955

RESUMO

Predictive biomarkers play an important role in our efforts to individualize pharmacotherapy, and within recent years, a number of different types of assays have been introduced. These biomarkers may potentially support the selection and dosage of specific drugs in order to maximize efficacy and minimize adverse reactions in the individual patient. However, in many instances, the scientific and clinical evidence is insufficient to support the prescribing decision. When predictive biomarkers are used to guide pharmacotherapy, it is important to secure that decisions are based on solid clinical evidence. Here, the regulatory authorities, especially the FDA, have been at the forefront in relation to regulate this type of biomarker assay in order to secure patient safety. The approval process for companion diagnostics is an example of this effort, where the scientific validity of the biomarker and assay is in focus. With the approaching implementation of the new IVD Regulation, greater attention will also be paid to analytical and clinical validity of biomarker assays in the EU. For any type of predictive biomarker assay, including pharmacogenetic and tumour profiling tests, the clinical evidence needs to be in place before they are used routinely in the clinic.


Assuntos
Bioensaio/instrumentação , Biomarcadores/análise , Testes Farmacogenômicos/instrumentação , Bioensaio/métodos , Bioensaio/normas , Aprovação de Teste para Diagnóstico , União Europeia , Testes Farmacogenômicos/métodos , Testes Farmacogenômicos/normas , Medicina de Precisão/métodos , Kit de Reagentes para Diagnóstico/normas , Estados Unidos , United States Food and Drug Administration/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...